Article 210 Branch Circuits Part 3 Required Outlets 210.70

Gcancio Avatar

210.70 Lighting Outlets Required. Let me start this article needs to revamped. I don’t know anyone that likes a dark room. Well at least a room that has a standing light. This is were the code is lacking for the customer and favors the contractor. This is the bar minimum a contractor needs to do in a new construction. Even when there is an addition to a dwelling they will, if not specified, install a switch with an outlet for a stand alone lamp. So buyer beware, when specking out a house this needs to speculated. The outlet is cheaper by far. But it’s not something that you will live with for very long. This article could be an upsell for contractors, at least I believe. The rest of the article goes through and says the requirements for different rooms. This article added kitchen to the rooms that were omitted for some reason.

“Lighting outlets shall be installed where specified in 210.70(A), (B), and (C).

(A)Dwelling Units. In dwelling units, lighting outlets shall be installed in accordance with 210.70(A)(1), (A)(2), and (A)(3).

(1) Habitable Rooms. At least one wall switch–controlled lighting outlet shall be installed in every habitable room, kitchen, and bathroom.

Exception No. 1: In other than kitchens and bathrooms, one or more receptacles controlled by a wall switch shall be permitted in lieu of lighting outlets.

Exception No. 2: Lighting outlets shall be permitted to be controlled by occupancy sensors that are (1) in addition to wall switches or (2) located at a customary wall switch location and equipped with a manual override that will allow the sensor to function as a wall switch.

(2) Additional Locations. Additional lighting outlets shall be installed in accordance with the following:

(1) At least one wall switch–controlled lighting outlet shall be installed in hallways, stairways, attached garages, and detached garages with electric power.

(2) For dwelling units, attached garages, and detached garages with electric power, at least one wall switch–controlled lighting outlet shall be installed to provide illumination on the exterior side of outdoor entrances or exits with grade-level access. A vehicle door in a garage shall not be considered as an outdoor entrance or exit.

(3) Where one or more lighting outlet(s) are installed for interior stairways, there shall be a wall switch at each floor level, and landing level that includes an entryway, to control the lighting outlet(s) where the stairway between floor levels has six risers or more.

Exception to (A)(2)(1), (A)(2)(2), and (A)(2)(3): In hallways, in stairways, and at outdoor entrances, remote, central, or automatic control of lighting shall be permitted.

(4)Lighting outlets controlled in accordance with 210.70(A)(2)(3) shall not be controlled by use of dimmer switches unless they provide the full range of dimming control at each location.

(3)Storage or Equipment Spaces. For attics, underfloor spaces, utility rooms, and basements, at least one lighting outlet containing a switch or controlled by a wall switch shall be instal‐ led where these spaces are used for storage or contain equipment requiring servicing. At least one point of control shall be at the usual point of entry to these spaces. The lighting outlet shall be provided at or near the equipment requiring servicing.

(B) Guest Rooms or Guest Suites. In hotels, motels, or similar occupancies, guest rooms or guest suites shall have at least one wall switch–controlled lighting outlet installed in every habitable room and bathroom.

Exception No. 1: In other than bathrooms and kitchens where provided, one or more receptacles controlled by a wall switch shall be permitted in lieu of lighting outlets.

Exception No. 2: Lighting outlets shall be permitted to be controlled by occupancy sensors that are (1) in addition to wall switches or (2) located at a customary wall switch location and equipped with a manual override that allows the sensor to function as a wall switch.

(C) For attics and underfloor spaces, utility at least one lighting outlet containing a

switch or controlled by a wall switch shall be. At least one point of control shall be at the usual point of entry to these spaces. The lighting outlet shall be provided at or near the equipment requiring servicing.”


One response

  1. Article 220 Branch-Circuit, Feeder, and Service Load Calculations part 2 220.14 – The Electrical Code

    […] 220.12 General Lighting Loads by Occupancy. Then it has a third standard that I linked to here 210.70. (K) this part of the article deals with the section of the bank and office buildings. So what they […]

    Like